We perform various steam turbine valve component inspections for steam turbines all across the country.  We recently completed a shop inspection of D-11 steam turbine valve components at our world-class facility in Gainesville, Georgia.  The original scope of work for these valves was to disassemble, clean, dimensionally inspect, perform NDE, and provide inspection results and recommendations to the client for disposition. “As Found” dimensional data along with the final NDE inspections were provided to the customer to aide in their decision-making process.

After component inspections are complete we communicate with the customer to determine the best course of action for their components, execute the repair/replacement (if necessary), and return the valve assemblies to the site.

In this instance we inspected the following D-11 steam turbine valves:

  • Reheat Stop Valve
    • RHSV-Left
    • RHSV-Right
  • Intercept Valve
    • IV-Left
    • IV-Right

If you have any upcoming steam turbine valve component inspections please CONTACT US today and we can send you a sample inspection report, as well as a quotation for completing the inspections.